Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 16 , ISSUE 2 ( May-August, 2021 ) > List of Articles

Original Article

Accuracy and Efficacy of Software-guided Bony Realignment in Periarticular Deformities of the Lower Limb

Pritish Singh, Dhananjay Sabat, Saurabh Dutt, Rakesh Sehrawat, Balu Prashanth, Anubhav Vichitra, Vinod Kumar

Keywords : Deformity severity score, Ilizarov fixator, Ortho-SUV frame, Periarticular deformities, Software-guided bony realignments

Citation Information : Singh P, Sabat D, Dutt S, Sehrawat R, Prashanth B, Vichitra A, Kumar V. Accuracy and Efficacy of Software-guided Bony Realignment in Periarticular Deformities of the Lower Limb. 2021; 16 (2):65-70.

DOI: 10.5005/jp-journals-10080-1524

License: CC BY-NC-SA 4.0

Published Online: 27-10-2021

Copyright Statement:  Copyright © 2021; The Author(s).


Abstract

Aim and objective: Software-guided realignment is proposed as an easy and accurate method of achieving simultaneous multiaxial correction. The accuracy and efficacy in periarticular problems have not been investigated fully. This study investigates the results and possible clinical benefits. Materials and methods: A retrospective review was performed in 24 patients with 27 periarticular deformities of the lower limb treated by the Ilizarov technique. Bony realignment was achieved by a software-guided hexapod realignment device. The deformity category, deformity severity score (DSS) and individual deformity component scores were measured for objective quantification of each deformity. The periarticular level, number of manoeuvres, correction period and any difficulties in the execution of the correction manoeuvre were noted. Pre-procedure and post-procedure values of deformity parameters were analysed to estimate the accuracy and efficacy of the realignment device. Results: The correction manoeuvre was accomplished successfully in all patients except two. The mean correction period was 14.9 days (range, 5–38 days). The mean pre-procedure DSS was 18.7 (range 6.3–27.3), which reduced to a mean post-procedure value of 1.5 (range, 0–7.9) with a 92.0% deformity correction (p-value < 0.001)). There was a significant reversal of individual deformity components. DSS values were achieved to an excellent level (< 3.5) in 25 deformities and to good and poor levels in one deformity, respectively. Conclusion: Software-guided realignments are effective for accurate realignment of periarticular deformities using Ilizarov fixators. These devices offer simultaneous multidimensional corrections even in complex multiplanar deformities and simplify the task of deformity correction. Clinical significance: The present study assesses the accuracy and efficacy of software-guided realignments using novel concepts of deformity category, DSS and individual deformity component scores, which may overcome some of the shortcomings of conventional assessment methods.


HTML PDF Share
  1. Keshet D, Eidelman M. Clinical utility of the Taylor spatial frame for limb deformities. Orthop Res Rev 2017;9:51–61. DOI: 10.2147/ORR.S113420.
  2. Hughes A, Parry M, Heidari N, et al. Computer hexapod-assisted orthopaedic surgery for the correction of tibial deformities. J Orthop Trauma 2016;30(7):e256–e261. DOI: 10.1097/BOT.0000000000000544.
  3. Ganger R, Radler C, Speigner B, et al. Correction of post-traumatic lower limb deformities using the Taylor spatial frame. Int Orthop 2010;34(5):723–730. DOI: 10.1007/s00264-009-0839-5.
  4. Manner HM, Huebl M, Radler C, et al. Accuracy of complex lower-limb deformity correction with external fixation: a comparison of the Taylor Spatial Frame with the Ilizarov ring fixator. J Child Orthop 2007;1(1):55–61. DOI: 10.1007/s11832-006-0005-1.
  5. Solomin LN, Paley D, Shchepkina EA, et al. A comparative study of the correction of femoral deformity between the Ilizarov apparatus and Ortho-SUV Frame. Int Orthop 2014;38(4):865–872. DOI: 10.1007/s00264-013-2247-0.
  6. Eren I, Eralp L, Kocaoglu M. Comparative clinical study on deformity correction accuracy of different external fixators. Int Orthop 2013;37(11):2247–2252. DOI: 10.1007/s00264-013-2116-x.
  7. Solomin LN, Utekhin AI, Vilensky VA. Deformity correction and fracture treatment using the software-based ortho-SUV frame. In: The basic principles of external skeletal fixation using the ilizarov and other devices. Milan: Springer, 2012, pp. 705–803.
  8. Wright J, Sabah SA, Patel S, et al. The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator. Strat Traum Limb Recon 2017;12(2):127–131. DOI: 10.1007/s11751-017-0287-5.
  9. Tetsworth KD, Paley D. Accuracy of correction of complex lower-extremity deformities by the Ilizarov method. Clin Orthop Relat Res 1994;301:102–110. Available at: https://pubmed.ncbi.nlm.nih.gov/8156660/
  10. Paley D. Rotation and angulation-rotation deformities. In: Principles of deformity correction. Berlin: Springer, 2002, pp. 235–268.
  11. Paley D. History and science behind the six-axis correction external fixation devices in orthopaedic surgery. Oper Tech Orthop 2011;21(2):125–128. DOI: 10.1053/j.oto.2011.01.011.
  12. Vilensky VA, Pozdeev AP, Bukharev EV, et al. Orthopedic hexapods: history, present and prospects. Pediatr Traumatol Orthop Reconstr Surg 2015;3(1):61–69. DOI:10.17816/PTORS3161-69.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.