Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 14 , ISSUE 3 ( September-December, 2019 ) > List of Articles

Original Article

Preliminary Results with the Shape Memory Nail: A Self-contained Distal Locking Mechanism for Diaphyseal Femur Fractures

Nando Ferreira, Luan Nieuwoudt

Keywords : Distal locking, Femur fracture, Intramedullary nail, Memory metal, Nitinol

Citation Information : Ferreira N, Nieuwoudt L. Preliminary Results with the Shape Memory Nail: A Self-contained Distal Locking Mechanism for Diaphyseal Femur Fractures. 2019; 14 (3):115-120.

DOI: 10.5005/jp-journals-10080-1437

License: CC BY-NC-SA 4.0

Published Online: 23-07-2020

Copyright Statement:  Copyright © 2019; The Author(s).


Abstract

Distal interlocking of intramedullary nails can be challenging if not done regularly and can be associated with a prolonged operating time and excessive radiation exposure. Multiple techniques have been developed to overcome these problems but all still rely on conventional distal locking methods. Between December 2011 and March 2013, 18 patients with diaphyseal femur fractures were treated with the shape memory nail (Orthofix, Verona, Italy). These nails use self-contained nitinol memory metal ‘wings’ at the distal aspect of the nail to provide rotational and longitudinal stability. We observed fracture union in all 18 cases with no non-unions, rotational malalignments or peri-prosthetic infections. Median theatre time was 35 (18–71) minutes and median total radiation time was 50 (20–209) seconds. The shape memory nail (Orthofix, Verona, Italy) is an attractive alternative to conventional interlocking femoral nails. It provides sufficient stability to allow fracture union while decreasing theater time and limiting radiation exposure.


HTML PDF Share
  1. Webb LX, Gristina AG, Fowler HL. Unstable femoral shaft fractures: a comparison of interlocking nailing versus traction and casting methods. J Orthop Trauma 1988;2(1):10–12. DOI: 10.1097/00005131-198802000-00003.
  2. Sugarman ID, Adam I, Bunker TD. Radiation dosage during AO locking femoral nailing. Injury 1988;19(5):336–338. DOI: 10.1016/0020-1383(88)90107-6.
  3. Hoffmann M, Schroder M, Lehmann W, et al. Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system. J Trauma Acute Care Surg 2012;73(1):243–248. DOI: 10.1097/TA.0b013e31824b0088.
  4. Krettek C, Könemann B, Miclau T, et al. A new mechanical aiming device for the placement of distal interlocking screws in femoral nails. Arch Orthop Trauma Surg 1998;117(3):147–152. DOI: 10.1007/s004020050215.
  5. Krettek C, Konemann B, Miclau T, et al. A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop Relat Res 1999(364):267–275. DOI: 10.1097/00003086-199907000-00033.
  6. Owen TD, Coorsh J. Insertion of the distal locking screws in femoral nailing: a simplified technique. Injury 1993;24(2):101–103. DOI: 10.1016/0020-1383(93)90198-f.
  7. Rohilla R, Singh R, Magu N, et al. Nail over nail technique for distal locking of femoral intramedullary nails. Int Orthop 2009;33(4):1107–1112. DOI: 10.1007/s00264-008-0579-y.
  8. Goodall JD. An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury 1991;22(4):339. DOI: 10.1016/0020-1383(91)90026-b.
  9. Arlettaz Y, Dominguez A, Farron A, et al. Distal locking of femoral nails: evaluation of a new radiation-independent targeting system. J Orthop Trauma 2012;26(11):633–637. DOI: 10.1097/BOT.0b013e318242d8b7.
  10. Bonshahi AY, Cowey A, Vhadra R. A simple distal interlocking aid for intramedullary nails. J Postgrad Med 2003;49(1):99–100. DOI: 10.4103/0022-3859.912.
  11. Keenan J, Stitson D, Charnley GJ. McIndoe's scissors - a simple technique to aid distal locking of an intramedullary nail. Ann R Coll Surg Engl 2000;82(2):143–144.
  12. Soni R, Mehta S, Singh J, et al. Radiation-free insertion of distal interlocking screw in tibial and femur nailing: a simple technique. J Surg Tech Case Report 2012;4(1):15–18. DOI: 10.4103/2006-8808.100346.
  13. Anastopoulos G, Ntagiopoulos PG, Chissas D, et al. Distal locking of tibial nails: a new device to reduce radiation exposure. Clin Orthop Relat Res 2008;466(1):216–220. DOI: 10.1007/s11999-007-0036-z.
  14. Krettek C, Konemann B, Farouk O, et al. Experimental study of distal interlocking of a solid tibial nail: radiation-independent distal aiming device (DAD) versus freehand technique (FHT). J Orthop Trauma 1998;12(6):373–378. DOI: 10.1097/00005131-199808000-00001.
  15. Babis GC, Benetos IS, Karachalios T, et al. Eight years’ clinical experience with the orthofix tibial nailing system in the treatment of tibial shaft fractures. Injury 2007;38(2):227–234. DOI: 10.1016/j.injury.2006.07.030.
  16. Pennig D, Oppenheim W, Faccioli G, et al. Intramedullary locked nailing of femur and tibia: insertion of distal locking screws without image intensifier. Injury 1997;28(4):323–326. DOI: 10.1016/s0020-1383(97)00004-1.
  17. Chakraborty MK, Thapa P, Sathian B. Surgical implant generation network (SIGN) solid intramedullary interlocking nail in the lower extremity: an observational study from western Nepal. J Clin Diag Res 2011;5(8):1614–1617.
  18. Pardiwala D, Prabhu V, Dudhniwala G, et al. The AO distal locking aiming device: an evaluation of efficacy and learning curve. Injury 2001;32(9):713–718. DOI: 10.1016/s0020-1383(01)00100-0.
  19. Krettek C, Mannss J, Miclau T, et al. Deformation of femoral nails with intramedullary insertion. J Orthop Res 1998;16(5):572–575. DOI: 10.1002/jor.1100160508.
  20. Goulet JA, Londy F, Saltzman CL, et al. Interlocking intramedullary nails. n improved method of screw placement combining image intensification and laser light. Clin Orthop Relat Res 1992(281): 199–203.
  21. Stathopoulos I, Karampinas P, Evangelopoulos DS, et al. Radiation-free distal locking of intramedullary nails: evaluation of a new electromagnetic computer-assisted guidance system. Injury 2013;44(6):872–875. DOI: 10.1016/j.injury.2012.08.051.
  22. Shoham M, Burman M, Zehavi E, et al. Bone-mounted miniature robot for surgical procedures: concept and clinical applications. IEEE Trans Rob Autom 2003;19(5):893–901. DOI: 10.1109/TRA.2003.817075.
  23. Yaniv Z, Joskowicz L. Precise robot-assisted guide positioning for distal locking of intramedullary nails. IEEE Trans Med Imaging 2005;24(5):624–635. DOI: 10.1109/TMI.2005.844922.
  24. Pelton AR, Stockel D. A guide to shape memory and superelasticity in nitinol medical devices. Minim Invasive Ther Allied Technol 2004;13(4):218–221. DOI: 10.1080/13645700410017236.
  25. Stoeckel D, Pelton A, Duerig T. Self-expanding nitinol stents: material and design considerations. Eur Radiol 2004;14(2):292–301. DOI: 10.1007/s00330-003-2022-5.
  26. Duerig T, Pelton A, Stockel D. An overview of nitinol medical applications. Mater Sci Eng 1999(A273–275):149–160. DOI: 10.1016/S0921-5093(99)00294-4.
  27. Cutright DE, Bhaskar SN, Perez B, et al. Tissue reaction to nitinol wire alloy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1973;35(4):578–584. DOI: 10.1016/0030-4220(73)90017-0.
  28. Rose DM, Smith TO, Nielsen D, et al. Expandable intramedullary nails in lower limb trauma: a systematic review of clinical and radiological outcomes. Strat Traum Limb Recon 2013;8(1):1–12. DOI: 10.1007/s11751-013-0156-9.
  29. Kapoor SK, Kataria H, Boruah T, et al. Expandable self-locking nail in the management of closed diaphyseal fractures of femur and tibia. Indian J Orthop 2009;43(3):264–270. DOI: 10.4103/0019-5413. 53457.
  30. Sipahioglu S, Zehir S, Sarikaya B, et al. Comparision of the expandable nail with locked nail in the treatment of closed diaphyseal fractures of femur. Niger J Clin Pract 2017;20(7):792–798. DOI: 10.4103/1119-3077.212452.
  31. Smith WR, Ziran B, Agudelo JF, et al. Expandable intramedullary nailing for tibial and femoral fractures: a preliminary analysis of perioperative complications. J Orthop Trauma 2006;20(5):310–314. DOI: 10.1097/00005131-200605000-00002; discussion 5-6.
  32. Maugans CJ, Damron TA. Femoral fixion expandable nail implant failure and difficult extraction: a case report. Tech Orthop 2015; 30(1):e1–e4. DOI: 10.1097/BTO.0000000000000087.
  33. Lepore L, Lepore S, Maffulli N. Intramedullary nailing of the femur with an inflatable self-locking nail: comparison with locked nailing. J Orthop Sci 2003;8(6):796–801. DOI: 10.1007/s00776-003- 0709-8.
  34. Horn A, Maqungo S, Roche S, et al. Distal locking in femoral intramedullary nails: free-hand technique versus Sureshot® assisted. Orthop Proc 2013;95-B(Supp. 14):20.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.