Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 13 , ISSUE 2 ( August, 2018 ) > List of Articles

Original Article

Role of ultrasound in detection of radiolucent foreign bodies in extremities

Mehraj D. Tantray, Asim Rather, Qazi Manaan, Irfan Andleeb, Mir. Mohammad, Yasmeena Gull

Keywords : Extremities, Foreign body, Radiolucent, Ultrasonography

Citation Information : Tantray MD, Rather A, Manaan Q, Andleeb I, Mohammad M, Gull Y. Role of ultrasound in detection of radiolucent foreign bodies in extremities. 2018; 13 (2):81-85.

DOI: 10.1007/s11751-018-0308-z

License: CC BY-NC-SA 4.0

Published Online: 01-06-2016

Copyright Statement:  Copyright © 2018; The Author(s).


Abstract

Removal of foreign bodies from soft tissues in emergency is very challenging and becomes more problematic when it is radiolucent. Blind exploration is sometimes hazardous for patients especially when it is in proximity to a vessel or a nerve or an overlying tendon. The purpose of this study was to determine the accuracy of ultrasonography (USG) in detecting radiolucent soft tissue foreign bodies in the extremities. From January 2014 to January 2016, 120 patients with either a positive history or clinically suspected soft tissue foreign body and negative radiography were evaluated by USG with a high-frequency (13–6 MHz) linear-array transducer. The sonographic findings were used to guide surgical exploration. Out of 120 patients who underwent surgical exploration, USG was positive in 114 cases, and foreign body was retrieved in 108 cases, and among the six cases where USG was negative, foreign body was retrieved from one case. In one case with strong clinical suspicion of foreign body USG was falsely negative. Majority of foreign bodies were removed from foot (69 cases) and hands (26 cases), and rest of foreign bodies were removed from ankle (4 cases), wrist (3 cases), thigh (2 cases), leg (1 case), knee (2 cases), forearm (2 cases). Accuracy, sensitivity, and positive predictive value were determined as 94.16, 99.08, and 94.13%, respectively. The real-time high-frequency USG is a highly sensitive and accurate tool for detecting and removing radiolucent foreign bodies which cannot be visualized by routine radiography.


PDF Share
  1. Boyse TD, Fessell DP, Jacobson JA, Lin J, van Holsbeeck MT, Hayes CW (2001) US of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 21:1251-1256
  2. Saki N, Nikakhlagh S, Rahim F, Abshirini H (2009) Foreign body aspirations in infancy: a 20-year experience. Int J Med Sci 6:322-328
  3. Borgohain B, Borgohain N, Nandique A, Gogoi PJ (2012) Case report and brief review of literature on sonographic detection of accidentally implanted wooden foreign body causing persistent sinus. Crit Ultrasound J 4:10
  4. Yanay O, Vaughan DJ, Diab M, Brownstein D, Brogan TV (2001) Retained wooden foreign body in a child's thigh complicated by severe necrotizing fasciitis: a case report and discussion of imaging modalities for early diagnosis. Pediatr Emerg Care 17:354-355
  5. Fakoor M (2006) Prolonged retention of an intra-medullary wooden foreign body. Pak J Med Sci 22:78-79
  6. Freund EI, Weigl K (1984) Foreign body granuloma: a cause of trigger thumb. J Hand Surg Br 9:210
  7. Choudhari KA, Muthu T, Tan MH (2001) Progressive ulnar neuropathy caused by delayed migration of a foreign body. Br J Neurosurg 15:263-265
  8. Yang SS, Bear BJ, Wieland AJ (1995) Rupture of the flexor pollicis longus tendon after 30 years due to migration of a retained foreign body. J Hand Surg Br 20:803-805
  9. Jablon M, Rabin SI (1988) Late flexor pollicis longus tendon rupture due to retained glass fragments. J Hand Surg Am 13:713-716
  10. Rainer C, Schoeller T, Wechselberger G, Bauer T, Hussl H (2000) Median nerve injury caused by missed foreign body. Scand J Plast Reconstr Surg Hand Surg 34:401-403
  11. Azzopardi EA, Xuereb CB, Iyer S (2009) Pyogenic granuloma as a surrogate indicator of deep seated foreign bodies: a case report. Cases J 2:7354
  12. James W, Robert A, Suzanne M (1995) Vascular complications of a foreign body in the hand of an asymptomatic patient. Ann Plast Surg 34:92-94
  13. Meurer WJ (2009) Radial artery pseudo aneurysm caused by occult retained glass from a hand laceration. Pediatr Emerg Care 25:255-257
  14. Coombs CJ, Mutimer KL, Slattery PG, Wise AG (1990) Hide and seek: pre-operative ultrasound localization of non-radio-opaque foreign bodies. Aust N Z J Surg 60:989-991
  15. Dunn JD (1987) Risk management in emergency medicine. Emerg Med Clin N Am 5:51-69
  16. Graham DD Jr (2002) Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med 22(1):75-79
  17. Peterson JJ, Bancroft LW, Kransdorf MJ (2002) Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol 178(3):557-562
  18. Crowford R, Matheson AB (1989) Clinical value of ultrasonography in detection and removal of radiolucent foreign bodies. Injury 20:341-343
  19. Ober CP, Jones JC, Larson MM, Lanz OI, Werre SR (2008) Comparison of ultrasound, computed tomography, and magnetic resonance imaging in detection of acute wooden foreign bodies in the canine manus. Vet Radiol Ultrasound 49(5):411-418
  20. Venter NG, Jamel N, Marques RG, Djahjah F, MendonçaLde S (2005) Evaluation of radiological methods for detection of wood foreign body in animal model. Acta Cir Bras 20(Suppl 1):34-41
  21. Little CM, Parker MG, Callowich MC, Sartori JC (1986) The ultrasonic detection soft tissue foreign bodies. Investig Radiol 21:275-277
  22. Donaldson J (1991) Radiographic imaging of foreign bodies in the hand. Hand Clin 7:125-134
  23. Anderson MA, Newmeyer WL, Kilgore ES (1982) Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg 144:63-67
  24. Conti RJ, Shinder M (1991) Soft tissue calcification induced by local corticosteroid injection. J Foot Surg 30:34-37
  25. Flom LL, Ellis GL (1992) Radiologic evaluation of foreign bodies. Emerg Med Clin North Am 10:163-176
  26. Dumarey A, De Maeseneer M, Ernst C (2004) Large wooden foreign body in the hand: recognition of occult fragments with ultrasound. Emerg Radiol 10(6):337-339
PDF Share