Citation Information :
Wali MG, Nazir A, Latoo IA, Bhat NA, Baba OK, Sharma S. Internal fixation of shaft humerus fractures by dynamic compression plate or interlocking intramedullary nail: a prospective, randomised study. 2014; 9 (3):133-140.
Compare the results of internal fixation of shaft of humerus fractures using dynamic compression plating (DCP) or antegrade interlocking intramedullary nail (IMN). Fifty patients with diaphyseal fracture of the shaft of the humerus and fulfilling the inclusion criterion were randomly assigned to one of the two groups. Twenty-five patients were managed with closed antegrade interlocking intramedullary nail, and 25 underwent open reduction and internal fixation using dynamic compression plating. The mean age of patients with IMN fixation was 37.28 years (SD 12.26) and 37.72 years (SD 12.70) for those who underwent plating. Road traffic accident was the most common mode of injury in both groups. There was a statistically significant difference between the two groups with respect to duration of hospital stay, operative time and blood loss. There was no significant difference between the two groups in terms of union or complications. The functional assessment at the end of 1 year between the two groups did not show any significant difference in outcome. Antegrade interlocking IMN and DCP fixation are comparable when managing diaphyseal shaft of humerus fractures with respect to union rates and complications. Although shoulder related complications are more in the IMN group, however, it is associated with shorter hospital stay, lesser operative time and less blood loss. This makes interlocking IMN an effective option in managing these fractures.
Brinker MR, O'Connor DP (2004) The incidence of fractures and dislocations referred for orthopaedic services in a capitated population. J Bone Joint Surg Am 86:290-297
Schemitsch EH, Bhandari M (2001) Fractures of the diaphyseal humerus. In: Browner BD, Jupiter JB, Levine AM, Trafton PG (eds) Skeletal trauma, 3rd edn. WB Saunders, Toronto, pp 1481-1511
Bohler L (1965) Conservative treatment of fresh closed fractures of humerus. J Trauma 5:464-468
Sarmiento A, Zagorski JB, Zych DO, Latta LL, Capps CA (2000) Functional bracing for the treatment of fractures of humeral diaphysis. J Bone Joint Surg Am 82:478-486
Koch PP, Gross DF, Gerber C (2002) The results of functional (Sarmiento) bracing of humeral shaft fractures. J Shoulder Elbow Surg 11:143-150
Rommens PM, Verbruggen J, Broos PL (1995) Retrograde locked nailing of humeral shaft fractures. A review of 39 patients. J Bone Joint Surg Br 77:84-89
Ulrich C (1996) Surgical treatment of humeral diaphyseal fractures. In: Flatow E, Ulrich C (eds) Humerus. Butterworth- Heinemann, Oxford, pp 128-143
Foulk DA, Szabo RM (1995) Diaphyseal humeral fractures; natural history and occurrence of nonunion. Orthopaedics 18:333-335
White WL, Mick GM, Mick CA, Brooker AF Jr, Weiland AJ (1987) Non union of humeral shaft. Clin Orthop 219:206-213
Heim D, Herkert F, Hess P, Regazzoni P (1993) Surgical treatment of humeral shaft fractures-the Basal experience. J Trauma 35:226-232
Robinson CM, Bell KM, Court-Brown CM, McQueen MM (1992) Locked nailing of humeral shaft fractures; experience in Edinburg over a two-year period. J Bone Joint Surg 74B:558-663
Paris H, Tropiano P, Clouet D'orval B, Chaudet H, Poitout DG (2000) Fractures of the shaft of the humerus: systematic plate fixation. Anatomic and functional results in 156 cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 86:346-359
Rodríguez-Merchán EC (1995) Compression plating versus hackethal nailing in closed humeral shaft fractures failing nonoperative reduction. J Orthop Trauma 9:194-197
Papasoulis E, Drosos GI, Ververidis AN et al (2010) Functional bracing of humeral shaft fractures. A review of clinical studies. Injury 41:e21-e27
Hoang-Kim A, Goldhahn J, Hak DJ (2012) Humeral shaft fractures. In: Bhandhari M, Gandhi R, Petrisor BA, Swiontkowski M (eds) Evidence-based orthopedics, 1st edn. Willey, Hoboken
Tsai CH, Fong YC, Chen YH, Hsu CJ, Chang CH, Hsu HC (2009) The epidemiology of traumatic humeral shaft fractures in Taiwan. Int Orthop 33:463-467
Ouyang H, Xiong J, Xiang P, Cui Z, Chen L, Yu B (2013) Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis. J Shoulder Elbow Surg 22:387-395
Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67:293-296
Ingman AM, Waters DA (1994) Locked intramedullary nailing of humeral shaft fractures. Implant design, surgical technique and clinical results. J Bone Joint Surg 76-Br:23-29
Fernandez FF, Matschke S, Hulsenbeck A, Egenolf M, Wentzensen A (2004) Five years' clinical experience with the undreamed humeral nail in the treatment of humeral shaft fractures. Injury 35:264-271
Sanzana ES, Dümmer RE, Castro JP, Díaz EA (2002) Intramedullary nailing of humeral shaft fractures. Int Orthop 26:211-213
McKee MD, Miranda MA, Riemer BL et al (1996) Management of humeral nonunion after the failure of locking intramedullary nails. J Orthop Trauma 10:492-499
Denies E, Nus S, Sermon A, Broos P (2010) Operative treatment of humeral shaft fractures. Comparison of plating and intramedullary nailing. Acta Orthop Belg 76:735-742
Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A Randomized controlled study. Intl Orthop 31:391-395
Bhandari M, Devereaux PJ, McKee MD, Schemitsch EH (2006) Compression plating versus intramedullary nailing of humeral shaft fractures: a meta-analysis. Acta Orthop 77:279-284
Brumback RJ, Bosse MJ, Poka A, Burgess AR (1986) Intramedullary stabilization of humeral shaft fractures in patients with multiple trauma. J Bone Joint Surg 68:960-970
Chao T-C, Chou W-Y, Chung J-C, Hsu C-J (2005) Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails. Int Orthop 29:88-91
Chapman JR, Henley MB, Agel J, Benca PJ (2000) Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates. J Orthop Trauma 14:162-166
Raghavendra S, Bhalodiya HP (2007) Internal fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: a prospective study. Indian J Orthop 41:214-218
Flinkkilä T, Hyvönen P, Siira P, Hämäläinen M (2004) Recovery of shoulder joint function after humeral shaft fracture: a comparative study between antegrade intramedullary nailing and plate fixation. Arch Orthop Trauma Sur 124:537-541
Stannard JP, Harris HW, McGwin G Jr et al (2003) Intramedullary nailing of humeral shaft fractures with a locking flexible nail. J Bone Joint Surg 85-Am:2103-2110
Chaudhary P, Karn NK, Shrestha BP, Khanal GP et al (2011) Randomized controlled trial comparing dynamic compression plate versus intramedullary interlocking nail for management of humeral shaft fractures. Health Renaissance 9:61-66
McCormack RG, Brien D, Buckley RE, McKee MD, Powell J, Schemitsch EH (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: a prospective, randomised trial. J Bone Joint Surg 82-B:336-339
Lin J (1998) Treatment of humeral shaft fractures with humeral locked nail and comparison with plate fixation. J Trauma 44:859-864
Kurup H, Hossain M, Andrew JG (2011) Dynamic compression plating versus locked intramedullary nailing for humeral shaft fractures in adults. Cochrane Database Syst Rev 15(6): CD005959. doi:10.1002/14651858