Can the material properties of regenerate bone be predicted with non-invasive methods of assessment? Exploring the correlation between dual X-ray absorptiometry and compression testing to failure in an animal model of distraction osteogenesis

Fergal Monsell, Andrew William Hughes, James Turner, Michael C. Bellemore, Lynne Bilston

Keywords : Distraction osteogenesis, DXA, Bone mineral density, Animal model

Citation Information : Monsell F, Hughes AW, Turner J, Bellemore MC, Bilston L. Can the material properties of regenerate bone be predicted with non-invasive methods of assessment? Exploring the correlation between dual X-ray absorptiometry and compression testing to failure in an animal model of distraction osteogenesis. 2014; 9 (1):45-51.

DOI: 10.1007/s11751-014-0188-9

License: CC BY-NC-SA 4.0

Published Online: 01-06-2018

Copyright Statement:  Copyright © 2014; The Author(s).


Abstract

Evaluation of the material properties of regenerate bone is of fundamental importance to a successful outcome following distraction osteogenesis using an external fixator. Plain radiographs are in widespread use for assessment of alignment and the distraction gap but are unable to detect bone formation in the early stages of distraction osteogenesis and do not quantify accurately the structural properties of the regenerate. Dual X-ray absorptiometry (DXA) is a widely available non-invasive imaging modality that, unlike X-ray, can be used to measure bone mineral content (BMC) and density quantitatively. In order to be useful as a clinical investigation; however, the structural two-dimensional geometry and density distributions assessed by DXA should reflect material properties such as modulus and also predict the structural mechanical properties of the regenerate bone formed. We explored the hypothesis that there is a relationship between DXA assessment of regenerate bone and structural mechanical properties in an animal model of distraction osteogenesis. Distraction osteogenesis was carried out on the tibial diaphysis of 41 male, 12 week old, New Zealand white rabbits as part of a larger study. Distraction started after a latent period of 24 h at a rate of 0.375 mm every 12 h and continued for 10-days, achieving average lengthening of 7.1 mm. Following an 18-day period of consolidation, the regenerate bone was subject to bone density measurements using a total body dual-energy X-ray densitometer. This produced measurement of BMC, bone mineral density (BMD) and volumetric bone mineral density (vBMD). The tibiae were then disarticulated and cleaned of soft tissue before loading in compression to failure using an Instron mechanical testing machine (Instron Corporation, Massachusetts USA). Using Spearman rank correlation and linear regression, there was a significant correlation between vBMD and the Modulus of Elasticity, Yield Stress and Failure Stress of the bone. No correlation was seen between BMC, BMD, vBMR and any mechanical parameter. DXA is a promising tool for the assessment of regenerate bone formed by DO during limb lengthening and requires further investigation.


PDF Share
  1. Ilizarov GA (1989) The tension-stress effect on the genesis and growth of tissues: part II. The influence of the rate and frequency of distraction. Clin Orthop Relat Res 239:263-285
  2. Ilizarov GA (1989) The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation. Clin Orthop Relat Res 238:249-281
  3. Ilizarov GA (1990) Clinical application of the tension-stress effect for limb lengthening. Clin Orthop Relat Res 250: 8-26
  4. Ilizarov GA, Ledyaev VI (1992) The replacement of long tubular bone defects by lengthening distraction osteotomy of one of the fragments. 1969. Clin Orthop Relat Res 280:7-10
  5. Noonan KJ, Leyes M, Forriol F, Canadell J (1998) Distraction osteogenesis of the lower extremity with use of monolateral external fixation. A study of two hundred and sixty-one femora and tibiae. J Bone Joint Surg Am 80(6):793-806
  6. Simpson AH, Kenwright J (2000) Fracture after distraction osteogenesis. J Bone Joint Surg Br 82(5):659-665
  7. De Bastiani G, Aldegheri R, Renzi-Brivio L, Trivella G (1987) Limb lengthening by callus distraction (callotasis). J Pediatr Orthop 7(2):129-134
  8. Saran N, Hamdy RC (2008) DEXA as a predictor of fixator removal in distraction osteogenesis. Clin Orthop Relat Res 466(12):2955-2961. doi:10.1007/s11999-008-0514-y
  9. Kolbeck S, Bail H, Weiler A, Windhagen H, Haas N, Raschke M (1999) Digital radiography. A predictor of regenerate bone stiffness in distraction osteogenesis. Clin Orthop Relat Res 366:221-228
  10. Bail HJ, Kolbeck S, Krummrey G, Weiler A, Windhagen HJ, Hennies K, Raun K, Raschke MJ (2002) Ultrasound can predict regenerate stiffness in distraction osteogenesis. Clin Orthop Relat Res 404:362-367
  11. Chotel F, Braillon P, Sailhan F, Gadeyne S, Gellon JO, Panczer G, Pedrini C, Berard J (2008) Bone stiffness in children: part II. Objectives criteria for children to assess healing during leg lengthening. J Pediatr Orthop 28(5):538-543. doi:10.1097/BPO.0b013e31817bb82e
  12. Harp JH, Aronson J, Hollis M (1994) Noninvasive determination of bone stiffness for distraction osteogenesis by quantitative computed tomography scans. Clin Orthop Relat Res 301:42-48
  13. Eyres KS, Bell MJ, Kanis JA (1993) New bone formation during leg lengthening. Evaluated by dual energy X-ray absorptiometry. J Bone Joint Surg Br 75(1):96-106
  14. Monsell F (2010) The effect of cytotoxic chemotherapy on the structural and material properties of regenerate bone in a rabbit model of limb lengthening. University Collece London, London
  15. Kaweblum M, Aguilar MC, Blancas E, Kaweblum J, Lehman WB, Grant AD, Strongwater AM (1994) Histological and radiographic determination of the age of physeal closure of the distal femur, proximal tibia, and proximal fibula of the New Zealand white rabbit. J Orthop Res 12(5):747-749. doi:10.1002/jor.1100120519
  16. Young JW, Kovelman H, Resnik CS, Paley D (1990) Radiologic assessment of bones after Ilizarov procedures. Radiology 177(1):89-93
  17. Shim JS, Chung KH, Ahn JM (2002) Value of measuring bone density serial changes on a picture archiving and communication systems (PACS) monitor in distraction osteogenesis. Orthopedics 25(11):1269-1272
  18. Eyres KS, Bell MJ, Kanis JA (1993) Methods of assessing new bone formation during limb lengthening. Ultrasonography, dual energy X-ray absorptiometry and radiography compared. J Bone Joint Surg Br 75(3):358-364
  19. Paley D (1990) Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res 250:81-104
  20. Reichel H, Lebek S, Alter C, Hein W (1998) Biomechanical and densitometric bone properties after callus distraction in sheep. Clin Orthop Relat Res 357:237-246
  21. Hudelmaier M, Kuhn V, Lochmuller EM, Well H, Priemel M, Link TM, Eckstein F (2004) Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)? Osteoporos Int 15(5):375-381. doi:10.1007/s00198-003-1551-8
  22. Markel MD, Chao EY (1993) Noninvasive monitoring techniques for quantitative description of callus mineral content and mechanical properties. Clin Orthop 293:37-45
  23. Markel MD, Wikenheiser MA, Morin RL, Lewallen DG, Chao EY (1991) The determination of bone fracture properties by dualenergy X-ray absorptiometry and single-photon absorptiometry: a comparative study. Calcif Tissue Int 48(6):392-399
  24. Burstein AH, Frankel VH (1971) A standard test for laboratory animal bone. J Biomech 4(2):155-158
  25. Ohyama M, Miyasaka Y, Sakurai M, Yokobori AT Jr, Sasaki S (1994) The mechanical behavior and morphological structure of callus in experimental callotasis. Biomed Mater Eng 4(4):273-281
  26. An HS, Xu R, Lim TH, McGrady L, Wilson C (1994) Prediction of bone graft strength using dual-energy radiographic absorptiometry. Spine (Phila Pa 1976) 19(20):2358-2362; discussion 2362-2353
  27. Black J, Perdigon P, Brown N, Pollack SR (1984) Stiffness and strength of fracture callus. Relative rates of mechanical maturation as evaluated by a uniaxial tensile test. Clin Orthop Relat Res 182:278-288
  28. Pilla AA, Mont MA, Nasser PR, Khan SA, Figueiredo M, Kaufman JJ, Siffert RS (1990) Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit. J Orthop Trauma 4(3):246-253
  29. Floerkemeier T, Hurschler C, Witte F, Wellmann M, Thorey F, Vogt U, Windhagen H (2005) Comparison of various types of stiffness as predictors of the load-bearing capacity of callus tissue. J Bone Joint Surg Br 87(12):1694-1699
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.