Abstract

We report a case of a 30-year old male, who presented with a right distal radius intra-articular fracture complicated by compartment syndrome. He was treated with fasciotomies and fracture fixation with a 3.5 mm LCP (Synthes), followed 7 days later by skin graft. Repeat radiographs 8 weeks later showed a break across the plate at the level of an unfilled screw hole over the fracture. He underwent exchange plating with a 2.4 mm LCP Distal Radius Plate (Synthes). This revision was complicated by an infected wound dehiscence 2 weeks later requiring multiple procedures. Radiographs at 20 weeks showed broken distal screws. A second revision was performed. At 12 months, the fracture had healed clinically and radiologically, but the three distal screws had broken. We discuss the multifactorial failures of the these three attempts at osteosynthesis, and which factors helped achieve osseous union. We also discuss the literature on volar locking plate breakage and conclude with the recommendations to avoid this rare complication.


PDF Share
  1. Downing ND, Karantana A (2008) A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 90(10):1271-1275
  2. Al-Rashid M, Theivendran K, Craigen MA (2006) Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br 88(12):1610-1612
  3. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316-322
  4. Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359-365
  5. Berglund LM, Messer TM (2009) Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 17(6):369-377
  6. De Baere T, Lecouvet F, Barbier O (2007) Breakage of a volar locking plate after delayed union of a distal radius fracture. Acta Orthop Belg 73(6):785-790
  7. Imade S, Matsuura Y, Miyamoto W, Nishi H, Uchio Y (2009) Breakage of a volar locking compression plate in distal radial fracture. Injury Extra 40(4):77-80
  8. Yukata K, Doi K, Hattori Y, Sakamoto S (2009) Early breakage of a titanium volar locking plate for fixation of a distal radius fracture: case report. J Hand Surg Am 34(5):907-909
  9. Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM (2003) Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am 28(1): 94-104
  10. Trease C, McIff T, Toby EB (2005) Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. J Hand Surg Am 30(4):756-763
  11. Cao J, Ozer K (2010) Failure of volar locking plate fixation of an extraarticular distal radius fracture: a case report. Patient Saf Surg 4(1):19
PDF Share