Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 3 , ISSUE 1 ( April, 2008 ) > List of Articles

Original Article

Percutaneous compression plating versus gamma nail for the treatment of pertrochanteric hip fractures

Rinaldo Giancola, Guido Antonini, Giacomo Delle Rose, Cornelio Crippa

Keywords : Hip fracture, Pertrochanteric fracture, Minimally invasive, Percutaneous, Fracture fixation, Percutaneous compression plate

Citation Information : Giancola R, Antonini G, Delle Rose G, Crippa C. Percutaneous compression plating versus gamma nail for the treatment of pertrochanteric hip fractures. 2008; 3 (1):9-14.

DOI: 10.1007/s11751-008-0032-1

License: CC BY-NC-SA 4.0

Published Online: 01-08-2019

Copyright Statement:  Copyright © 2008; The Author(s).


Abstract

The objective of this study is to compare percutaneous compression plating (PCCP) device with standard gamma nail (GN). A sample was prospectively followed and compared to a historical cohort: 82 intertrochanteric hip fractures in 81 patients treated with PCCP in 2004 versus 51 hip fractures treated with GN in 2003 (AO type 31A1, 31 A2). The main outcome measures were: surgery times, blood loss (Hb serum level and transfusions), complication, costs, for a 1-year follow-up. The minimally invasive PCCP technique resulted in a lower blood loss and consequently lower transfusion need (statistically significant), fewer implant-related complications and comparable surgery times. Overall surgical costs were lower for a comparable outcome in terms of healing and surgical time.


PDF Share
  1. Anderson GH, Raymakers R, Gregg PJ (1993) The incidence of proximal femoral fractures in an English county. J Bone Joint Surg Br 75(3):441-444
  2. Gallagher JC, Melton LJ, Riggs BL et al (1980) Epidemiology of fractures of the proximal femur in Rochester. Minnesota Clin Orthop 150:163-171
  3. Jensen JS (1980) Incidence of hip fracture. Acta Orthop Scand 51:511-513
  4. Symposium (1993) Hip fractures in the elderly: the coming epidemic. AAOS Annual Meeting, San Francisco
  5. Wallace WA (1983) The increasing incidence of fractures of the proximal femur: an orthopædic epidemic. Lancet 25:1413-1414
  6. Brandt SE, Lefever S, Janzing HM, Broos PL, Pilot P, Houben BJ (2002) Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: preliminary results. Injury Jun 33(5):413-418
  7. Gotfried Y (2000) Percutaneous compression plating of intertrochanteric hip fractures. J Orthop Trauma 14(7):490-495
  8. Janzing HM, Houben BJ, Brandt SE, Chhoeurn V, Lefever S, Broos P, Reynders P, Vanderschot P (2002) The Gotfried Per- Cutaneous Compression Plate versus the Dynamic Hip Screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and post-operative pain. J Trauma 52(2):293-298
  9. Kosygan KP, Mohan R, Newman RJ (2002) The Gotfried percutaneous compression plate compared with conventional/classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 84(1):19-22
  10. Krasheninnikoff M, Gramkow J, Torholm C, Gotfried PC (1998) C.P: A new method for osteosynthesis of intertrochanteric fractures of the femur. Acta Orthop Scand 280(Suppl 1):30-31
  11. Peyser A, Weil Y, Brocke L, Manor O, Mosheiff R, Liebergall M (2005) Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures. Injury 36(11):1343-1349
  12. Muller ME, Allgower M, Willenegger H (1996) Manual of internal fixation. Berlin, Springer-Verlag, 1970. Orthopædic trauma association committee for coding and classification. Fracture and dislocation compendium. J Orthop Trauma 10(Suppl 1):31-34
  13. Gotfried Y, Cohen B, Rotem A (2002) Biomechanical evaluation of the percutaneous compression plating system for hip fractures. J Orthop Trauma 16, 9:644-650
  14. Dodd R (1992) The risk of transfusion-transmitted infection. N Engl J Med 327:419-421
  15. Linden JV, Kaplan HS (1994) Transfusion errors: causes and effects. Transfus Med Rev 8:169-183
  16. Perkins H (1988) Transfusion-induced immunologic unresponsivness. Transfus Med Rev 2:196-203
  17. Dzupa V, Bartonicek J, Skala-Rosenbaum J, Prikazsky V (2002) Mortality in patients with proximal femoral fractures during the first year after the injury. Acta Chir Orthop Traumatol Cech 69(1):39-44 Czech
  18. Chirodian N, Arch B, Parker MJ (2005) Sliding hip screw fixation of trochanteric hip fractures: outcome of 1024 procedures. Injury 36(6):793-800. Epub 2005 Apr. 20
  19. Larsson S, Friberg S, Hansson LI (1990) Trochanteric fractures. Mobility, complications, and mortality in 607 cases treated with the sliding-screw technique. Clin Orthop Relat Res (260): 232-241
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.