Strategies in Trauma and Limb Reconstruction

Register      Login

VOLUME 14 , ISSUE 2 ( May-August, 2019 ) > List of Articles

Original Article

Bone Ninja Mobile App for Reverse Planning Method in Internal Limb Deformity and Lengthening Surgery

Alec Lik-Hang Hung, Philip K McClure, Jeanne M Franzone, Ahmed I Hammouda, Shawn C Standard, Wai-Wang Chau, John E Herzenberg

Keywords : Bone lengthening, Intramedullary lengthening, Limb deformity, Motorised implantable nail, Reverse planning

Citation Information : Hung AL, McClure PK, Franzone JM, Hammouda AI, Standard SC, Chau W, Herzenberg JE. Bone Ninja Mobile App for Reverse Planning Method in Internal Limb Deformity and Lengthening Surgery. 2019; 14 (2):72-76.

DOI: 10.5005/jp-journals-10080-1425

License: CC BY-NC-SA 4.0

Published Online: 01-08-2019

Copyright Statement:  Copyright © 2019; Jaypee Brothers Medical Publishers (P) Ltd.


Abstract

Aim: To report whether Bone Ninja (BN) is a reliable tool to teach the reverse planning method (RPM) for implantable intramedullary (IM) limblengthening devices and for deformity correction surgery. Background: Motorised fully implantable implantable intramedullary (IM) lengthening devices have been gaining popularity all over the world for limb-lengthening procedures. Multiple advantages have been demonstrated over external fixator-controlled lengthening. Mechanical axis deviation may result if careful preoperative planning and surgical intervention are not completed for femur cases. The RPM proposed by Baumgart has been shown to be an accurate means of arriving at the desired end point. The RPM addresses the ideal correction position accounting for length, angulation, and translation created during lengthening along the nail axis. The original description calls for the use of life-size paper tracings of the bone and large light boxes to allow planning. We propose an alternative method using a digital tool that is readily available. The BN mobile app was developed for patient/physician education and is available for the Apple iPad platform. Bone Ninja has been shown to have similar accuracy for measurements of the limb length and deformity angles when compared to the gold standard picture archiving and communication systems (PACSs). Technique: We used BN (version 4.2) on an iPad mini to perform the same RPM steps, using the same terminology originally described by Baumgart. Conclusion: Bone Ninja is a simple validated deformity correction tool with accuracy comparable to PACS. It is a reasonable alternative to paper/pencil cutouts for applying RPM for IM limb lengthening and deformity correction surgery. Clinical significance: We proposed a digitised RPM for internal limb-lengthening surgeries, which is highly feasible and practical to use conveniently without the need for the traditional tedious paper-cutting procedure and related equipment.


PDF Share
  1. Shabtai L, Specht SC, Standard SC, et al. Internal lengthening device for congenital femoral deficiency and fibular hemimelia. Clin Orthop Relat Res 2014;472(12):3860–3868. DOI: 10.1007/s11999-014-3572-3.
  2. Dahl M, Birch J, Motorized Intramedullary Lengthenings 2006–2013 Using Baumgart’s Technique. 23rd Annual Scientific Meeting of the Limb Lengthening and Reconstruction Society; New York, NY2013.
  3. Baumgart R, Betz A, Schweiberer L. A fully implantable motorized intramedullary nail for limb lengthening and bone transport. Clin Orthop Relat Res 1997(343):135–143. DOI: 10.1097/00003086-199710000-00023.
  4. Black SR, Kwon MS, Cherkashin AM, et al. Lengthening in congenital femoral deficiency: a comparison of circular external fixation and a motorized intramedullary nail. J Bone Joint Surg Am 2015;97(17): 1432–1440. DOI: 10.2106/JBJS.N.00932.
  5. Burghardt RD, Paley D, Specht SC, et al. The effect on mechanical axis deviation of femoral lengthening with an intramedullary telescopic nail. J Bone Joint Surg Br 2012;94(9):1241–1245. DOI: 10.1302/0301-620X.94B9.28672.
  6. Kocaoglu M, Eralp L, Bilen FE, et al. Fixator-assisted acute femoral deformity correction and consecutive lengthening over an intramedullary nail. J Bone Joint Surg Am 2009;91(1):152–159. DOI: 10.2106/JBJS.H.00114.
  7. Burghardt RD, Herzenberg JE, Burghardt MH. Trigonometric analysis of the mechanical axis deviation induced by telescopic intramedullary femoral lengthening nails. J Appl Biomech 2011;27(4):385–391. DOI: 10.1123/jab.27.4.385.
  8. Paley D, Herzenberg JE. Principles of deformity correction, vol. 1. Springer; 2002.
  9. Baumgart R. The reverse planning method for lengthening of the lower limb using a straight intramedullary nail with or without deformity correction. A new method. Oper Orthop Traumatol 2009;21(2):221–233. DOI: 10.1007/s00064-009-1709-4.
  10. Whitaker AT, Gesheff MG, Jauregui JJ, et al. Comparison of PACS and Bone Ninja mobile application for assessment of lower extremity limb length discrepancy and alignment. J Child Orthop 2016;10(5): 439–443. DOI: 10.1007/s11832-016-0761-5.
  11. Muthusamy S, Rozbruch SR, Fragomen AT. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery. Strategies Trauma Limb Reconstr 2016;11(3):199–205. DOI: 10.1007/s11751-016-0265-3.
  12. Steinberg EL, Segev E, Drexler M, et al. Preoperative planning of orthopedic procedures using digitalized software systems. Isr Med Assoc J 2016;18(6):354–358.
  13. Strickland NH. PACS (picture archiving and communication systems): filmless radiology. Arch Dis Child 2000;83(1):82–86. DOI: 10.1136/adc.83.1.82.
  14. Steinberg EL, Segev E. Pre-operative planning using the traumacad software system. US Radiol 2010;2(1):87–90.
  15. Galal S. The resolution axis method (RAM) for lengthening of the femur with or without associated frontal plane deformity (a new method). Strategies Trauma Limb Reconstr 2018;13(2):109–118. DOI: 10.1007/s11751-018-0312-3.
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.